AC Resonance Test System GDTF-120kVA/120kV
Click image to view full size image
Product: Views:222AC Resonance Test System GDTF-120kVA/120kV 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-08-12 18:13
  Inquiry
Details

I. Test Object and Requirement
 
The system is specially designed for AC withstand voltage test for below items, with below specifications and requirements.
 
Test Object Specifications Capacitance Test Frequency Test Voltage Test Time
Transformer 6/66kV/25000kVA  ≤0.012uF 45-65Hz 112kV 1min
Generator 6kV/12MW  ≤0.1uF 45-65Hz 15kV 1min
 
 
II. Working Environment
 
l Environmental temperature: -15ºC to 45ºC
l Related humidity: ≤ 90% RH
l Altitude: ≤ 3km
 
III. Technical Data
 
l Rated capacity: 120kVA
l Input power supply: Single phase 220V or three phase 380V; 50Hz
l Rated voltage: 30kV; 120kVA 
l Rated current: 4A; 1A 
l Working Frequency: 30-300Hz
l Output waveform: sine wave
 
l Waveform distortion rate: ≤1%
l Working time: constant working of 5mins under rated load; working of 1min, under 1.1 times of rated voltage
l Temperature rise: ≤65K after constant working of 5mins under rated load
l Quality factor: Q ≥30 (f=45Hz)
l Protective function: overcurrent, overvoltage and flashover protections for test object.
l Accuracy: 1.5% (RMS)
 
Combination utilization
 
Test object
 
HV Reactor  30kVA/30kV Selection of Excitation transformer output end
 
Testing voltage(kV)
6/66kV/25000kVA Transformer 4 set reactors in series 5kV ≤112kV
6kV/12MW Generator 1 set reactor 2.5kV ≤15kV
 
 
IV. Parameters for Individual Parts
 
1. Exciting Transformer  GDJL-6kVA/2.5/5kV/0.4kV (1 set)
 
l Rated capacity: 6kVA
l Input voltage: 0-400V, single phase
l Output voltage: 2.5/5kV
l Type: Dry type transformer
l Weight: approx. 38kg
 
2. Variable frequency power supply GDTF -6kW/220/380V (1 set)
 
l Rated output capacity: 6kW
l Working power supply: 220/380±10%V (single/ three phase, power frequency)
l Output voltage: 0-400V, single phase
l Rated input current: 13A
l Rated output current: 13A
l Voltage resolution: 0.01kV
l Voltage measuring accuracy: 0.5%
l Frequency adjusting range: 30-300Hz
 
l Frequency adjusting resolution:≤ 0.1Hz
l Frequency stability: 0.1%
l Working time: constant working of 5mins under rated capacity.
l Temperature rise: ≤ 65K after constant working of 5mins under rated capacity.
l Noise: ≤50dB
l Weight: 10kg
 
3. HV Reactor GDDK-30kVA/30kV (4 sets)
 
Rated capacity: 30kVA
Rated voltage: 30kV
 
Rated current: 1A
Inductance: 100H (per set)
Quality factor: Q ≥30 (f=45Hz)
Type: Dry type transformer 
Weight: approx. 50kg
 
4. Capactive Divider GDFR-120kV/800pF (1 set)
 
l Rated voltage: 120kV
l Capacitance: 800pF
l Dielectric loss: tgσ ≤0.5%
l Divider ratio: 1500:1
l Measuring accuracy: 1.5%
l Weight: approx. 9kg
 
 
5. Compensated capacitor  GDBC-120kV/8000pF (1 set)
 
l Rated voltage: 120kV
l Capacitance: 8000pF
l Weight: approx. 10kg
 
 
V. Packing List
 
No. Name Module No. & SPECS Quantity
1 Exciting Transformer GDJL-6kVA/2.5/5kV/0.4kV 1 set
2 Variable frequency power supply GDTF-6kW/220/380V 1 set
3 HV Reactor GDDK-30kVA/30kV  4 sets
4 Capactive Divider GDFR-120kV/800pF 1 set
5 Compensated capacitor GDBC-120kV/8000pF 1 set
6 Connecting Cable   1 set
7 Factory Test Report   1 copy
8 User's Guide   1 copy

Inquiry